전통맥진과 기기측정맥진의 상관성 연구

초록/요약

Objectives : The pulse diagnosis is an important and universally used method in Oriental Medicine. Since the traditional method of palpating the pulse relies on the subjective sense in the fingers of an Oriental Medical Doctor, there has been continued need for more objective method for pulse diagnosis. Recently, various pulse analyzers have been developed to meet such objective palpation and interpretation. Hence, the aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by pulse diagnosis apparatus using HJ pulse analyser, HS pulse analyser on Chon(寸), Kwan(關), Chuk(尺). Methods : Four korean medical doctors and HJ pulse analyser, HS pulse analyser have measured the velocity, the size, and the depth of pulse waves of 23 volunteers. First, four korean medical doctors measured pulse waves of volunteers. During measuring, four doctors were separated from each other and so were volunteers. And then, the pulse waves of volunteers were measured by HJ pulse analyser, HS pulse analyser. This was performed on the right Chon(寸), Kwan(關), Chuk(尺). Results : The study showed that the traditional method and the HJ pulse analyser method had the 60.9% matches on the values of the slow and rapid pulse condition(遲數), the HS pulse analyser method had the 78.3% matches on the values of the slow and rapid pulse condition(遲數). The study showed that the traditional method and the HJ pulse analyser method had the 56.5%(Chon), 65.2%(Kwan), 78.3%(Chuk) matches on the values of the small and big pulse condition(微細弱緩大), the HS pulse analyser method had the 65.2%(Chon), 13.0%(Kwan), 39.1%(Chuk) matches on the values of the small and big pulse condition(微細弱緩大). The study showed that the traditional method and the HJ pulse analyser method had the 43.5%(Chon), 26.1%(Kwan), 47.8%(Chuk) matches on the values of deep and superficial pulse condition(浮沈), the HS pulse analyser method had the 45.5%(Chon), 30.4%(Kwan), 36.8%(Chuk) matches on the values of the deep and superficial pulse condition(浮沈). Conclusions : According to these, we suggest that the pulse analyser is necessary to develope for high similarities with the traditional pulse diagnosis.

more

목차

ABSTRACT i
Ⅰ. 서 론 1
Ⅱ. 재료 및 방법 3
1 실험대상 3
2. 사용기기 3
3. 전통맥진 측정 3
4. 기기맥진 측정 3
1) HJ맥진기 3
2) HS맥진기 4
5. 수치화 정량화 방법 4
1) 맥의 빠르기 5
2) 맥의 크기 6
3) 맥의 깊이 7
6. 평가방법 7
Ⅲ. 결 과 9
1. 전통맥진과 기기측정맥진의 지수 정량화 9
1) 寸部 9
2) 關部 11
3) 尺部 13
2. 전통맥진과 기기측정맥진의 맥 빠르기 비교 15
3. 전통맥진과 기기측정맥진의 맥 크기 비교 19
4. 전통맥진과 기기측정맥진의 맥 깊이 비교 23
Ⅳ. 고 찰 27
Ⅴ. 결 론 36
참고문헌 38

more